General specifications |
Output voltage | 230 V - 50 Hz (0.1%) |
Output waveform | true sine |
Nominal battery voltage | 12 V |
Recommended battery capacity | ? 100 Ah |
Continuous power at 25 C / 77 F, cos phi 1 | 500 W |
Continuous power at 40 C / 104 F, cos phi 1 | 400 W |
Peak load (5 s) | 800 W |
AC connection | universal |
Galvanic isolation | yes |
Efficiency | 90 % |
Display/read-out | LED display |
Alarms | 4 alarm modes |
Dimensions, hxwxd | 210 x 130 x 60 mm 8.3 x 5.1 x 2.4 inch |
Weight | 1.22 kg 2.7 lb |
Compliance | CE, E-mark, ABYC A-31 |
Technical specifications |
Technology | high frequency, input & output fully isolated |
Low battery voltage, switches off at | 10 V, 0.5 V |
Low battery voltage, switches on at | 11 V, 0.5 V |
High battery voltage, switches off at | 16 V, 0.5 V |
High battery voltage, switches on at | 14.5 V, 0.5 V |
Max. ripple on DC (battery) | 10 % RMS |
Input current (nominal load) | 37.5 A |
No-load power consumption (ON mode) | 0.58 A - 7 W |
No-load power consumption (energy saving mode) | 0.33 A - 4 W |
Minimal DC fuse (slow blow) | 2x 40 A |
Minimal cable size | 1.5 mtr DC cable delivered as standard |
Harmonic distortion typical | < 6 % |
Cos phi | all power factors allowed |
Temperature range (ambient temp.) | -20 C to 40 C, derating power > 40 C -4 F to 104 F |
Cooling | natural/forced |
Switch off at (auto recover after cooling down) | 50 C 122 F |
Protection degree | IP23, vertical wall mounting |
Protections | over temperature, over load, short circuit, high/low battery voltage |
MasterBus compatible | no |