| General specifications |
| Output voltage | 230 V - 50 Hz (0.1%) |
| Output waveform | true sine |
| Nominal battery voltage | 12 V |
| Recommended battery capacity | ? 60 Ah |
| Continuous power at 25 C / 77 F, cos phi 1 | 300 W |
| Continuous power at 40 C / 104 F, cos phi 1 | 250 W |
| Peak load (5 s) | 600 W |
| AC connection | universal |
| Galvanic isolation | yes |
| Efficiency | 90 % |
| Display/read-out | LED display |
| Alarms | 4 alarm modes |
| Dimensions, hxwxd | 210 x 130 x 60 mm 8.3 x 5.1 x 2.4 inch |
| Weight | 1.16 kg 2.6 lb |
| Compliance | CE, E-mark, ABYC A-31 |
| Technical specifications |
| Technology | high frequency, input & output fully isolated |
| Low battery voltage, switches off at | 10 V, 0.5 V |
| Low battery voltage, switches on at | 11 V, 0.5 V |
| High battery voltage, switches off at | 16 V, 0.5 V |
| High battery voltage, switches on at | 14.5 V, 0.5 V |
| Max. ripple on DC (battery) | 10 % RMS |
| Input current (nominal load) | 22.5 A |
| No-load power consumption (ON mode) | 0.58 A - 7 W |
| No-load power consumption (energy saving mode) | 0.33 A - 4 W |
| Minimal DC fuse (slow blow) | 2x 40 A |
| Minimal cable size | 1.5 mtr DC cable delivered as standard |
| Harmonic distortion typical | < 6 % |
| Cos phi | all power factors allowed |
| Temperature range (ambient temp.) | -20 C to 40 C, derating power > 40 C -4 F to 104 F |
| Cooling | natural/forced |
| Switch off at (auto recover after cooling down) | 50 C 122 F |
| Protection degree | IP23, vertical wall mounting |
| Protections | over temperature, over load, short circuit, high/low battery voltage |
| MasterBus compatible | no |