| General specifications | 
| Output voltage | 230 V - 50 Hz (0.1%) | 
 | Output waveform | true sine | 
 | Nominal battery voltage | 12 V | 
 | Recommended battery capacity | ? 60 Ah | 
 | Continuous power at 25 C / 77 F, cos phi 1 | 300 W | 
 | Continuous power at 40 C / 104 F, cos phi 1 | 250 W | 
 | Peak load (5 s) | 600 W | 
 | AC connection | universal | 
 | Galvanic isolation | yes | 
 | Efficiency | 90 % | 
 | Display/read-out | LED display | 
 | Alarms | 4 alarm modes | 
 | Dimensions, hxwxd | 210 x 130 x 60 mm 8.3 x 5.1 x 2.4 inch | 
 | Weight | 1.16 kg 2.6 lb | 
 | Compliance | CE, E-mark, ABYC A-31 | 
 | Technical specifications | 
| Technology | high frequency, input & output fully isolated | 
 | Low battery voltage, switches off at | 10 V, 0.5 V | 
 | Low battery voltage, switches on at | 11 V, 0.5 V | 
 | High battery voltage, switches off at | 16 V, 0.5 V | 
 | High battery voltage, switches on at | 14.5 V, 0.5 V | 
 | Max. ripple on DC (battery) | 10 % RMS | 
 | Input current (nominal load) | 22.5 A | 
 | No-load power consumption (ON mode) | 0.58 A - 7 W | 
 | No-load power consumption (energy saving mode) | 0.33 A - 4 W | 
 | Minimal DC fuse (slow blow) | 2x 40 A | 
 | Minimal cable size | 1.5 mtr DC cable delivered as standard | 
 | Harmonic distortion typical | < 6 % | 
 | Cos phi | all power factors allowed | 
 | Temperature range (ambient temp.) | -20 C to 40 C, derating power > 40 C -4 F to 104 F | 
 | Cooling | natural/forced | 
 | Switch off at (auto recover after cooling down) | 50 C 122 F | 
 | Protection degree | IP23, vertical wall mounting | 
 | Protections | over temperature, over load, short circuit, high/low battery voltage | 
 | MasterBus compatible | no |