Input Voltage | 96-145VAC full performance |
| 70-96VAC automatically de-rate to 50% of full load current |
Frequency | 40Hz to 70Hz |
Nominal Input Current at Rated Output | <9Aac |
Voltage Measurement Accuracy | 8Vac |
Frequency Measurement Accuracy | 1Hz |
Output | |
Nominal Voltage | 12/24Vdc manual adjustable |
Output Current | Input voltage 96-145V,output current 75A for 12V modeoutput current 37.5A for 24V mode |
| Input voltage 70-96V,output current 37.5A for 12V modeoutput current 18.75A for 24V mode |
Rated Output Current | Manual adjustable |
Current Accuracy | 6% of full rated output current @25C, for target currents across the range from 10% rated output (for absorption exit criteria accuracy) to the current limit setpoint. |
Load Regulation | 1.5% |
Current Limit | 75-80Amp |
Dead-Battery Charging | 8-14.9Vdc at 100% of rated output current |
| 8-29.8Vdc at 100% of rated output current |
Selectable Battery Type | Open Lead-Acid, Gel, AGM, LiFePo4, adjustable |
Parallel Outputs | Maximum of two AC converter units connected in parallel |
Efficiency | 80% |
Protection | |
Input Over Voltage | Unit must be safe for input voltage up to 150VacRMS (and up to 215Vpeak), need not be operating. Above this level the unit may be damaged. |
Reverse Battery Polarity Protection | Non-destructive reverse battery polarity protection with fuses. Unit shall not sustain damage and shall meet all specifications after fuse replacement. |
Input Under-voltage | Unit must not be damaged for all input voltages from 0-300Vac. Shutdown or input current limit or other means may be applied when input voltage is out of normal operating range. |
Output over voltage12/24V mode | 12Vdc. Unit will shut down if Vcharging > Vcharging (target) + 1.0Vdc for more than 2 seconds; unit will restart when voltage <= Vcharging (target) for more than 2 seconds. For battery OVP the unit will restart in the same stage. |
| 24Vdc. Unit will shut down if Vcharging > Vcharging (target) + 1.5Vdc for more than 2 seconds; unit will restart when voltage <= Vcharging (target) for more than 2 seconds. For battery OVP the unit will restart in the same stage. |
Charger over temperature protection | The internal temperatures of the charger will be measured by NTC. Based on these measurements, unit will shut down if the temperature exceeds 105C. Unit will restart when environment temperature cools to 95 C. |
BTS(Battery Temperature Sensing) | The battery temperature sensor allows the charge controller tocontinuously adjust charge voltage / charge current based on actual battery temperature.When the battery temperature is over 40 C, unit will reduce the charging voltage to Float voltage, also it will reduce the Max charging current by 10% with every two degree of temperature rise.When the battery temperature is over 50 C, unit will shut down. |
Environmental | |
Operation temperature | Nominal ambient temperature: 25COperating Ambient Temperature range: -10C to 40C(On the heat sink of DC-DC part, if the temperature is over 90 ?, the Charger Current will be de-rate to 50% ; if the temperature is over 105 ?, the Unit will be shut down.) |
Relative humidity | 5?95% without condensation |
Noise | Unit requirements: below 50dB (A) measured at 1 m distance with fan full working. |
Storage Conditions Temperature | -20C to +80C |
Cooling | Smart fan control |
Safety | UL458?CSA22.2#107.1 |
Mechanical | |
Dimension (D x W x H) mm | 10.25" * 6.75" * 3.25" |
Unit Weight | 6.5 lb |
Boxed Weight | 7 lb |