| General specifications |
| Output voltage | 100/110/115/120 V - 50/60 Hz (selectable) |
| Output waveform | true sine |
| Nominal battery voltage | 12 V |
| Recommended battery capacity | > 100 Ah |
| Continuous power at 25 C / 77 F, cos phi 1 | 700 W |
| Continuous power at 40 C / 104 F, cos phi 1 | 700 W |
| Peak load (1 min) | < 810 W |
| Peak load (1 sec) | < 1230 W |
| AC connection | North American socket with GFCI |
| Efficiency | 91 % |
| Display/read - out | LED indication: battery voltage, load level, status |
| Alarms | potential free alarm contact |
| Dimensions, hxwxd | 200 x 330 x 83 mm 7.9 x 13.0 x 3.3 inch |
| Weight | 2,6 kg 5.7 lb |
| Approvals | safety: UL 458, EMC: FCC class B |
| Technical specifications |
| Technology | high frequency, input & output fully isolated |
| Low battery voltage, switches off at | 10,5 V |
| Low battery voltage, switches on at | 12,5 V |
| High battery voltage, switches off at | 16,5 V |
| High battery voltage, switches on at | 14,5 V |
| Input current (nominal load) | 70 A |
| No - load power consumption (ON mode) | < 1,5 A |
| No - load power consumption (energy saving mode) | < 0,1 A |
| Minimal DC fuse (slow blow) | 100 A |
| Minimal cable size | 25 mm2 |
| Harmonic distortion typical | < 5 % |
| Cos phi | all power factors allowed |
| Temperature range (ambient temp.) | - 20 C to 60 C, derating power > 40 C - 4 F to 140 F |
| Cooling | temperature and load controlled fan |
| Protection degree | IP21, horizontal wall mounting |
| Protections | over - temperature, overload, short circuit, high/low voltage, reverse polarity (fuse) |
| MasterBus compatible | no |