| Nominal Battery Voltage | 48V |
| Maximum Output Current | 200 amps 2 X 100 Amps, independent |
| PV Open Circuit Voltage VOC | 600VDC |
| Power Conversion Efficiency | 98% (Typical system) |
| Arc Fault and NEC 2020 Ground Fault Protection | Optional plugin modules - user installed |
| Charging Regulation | Bulk, Absorb, Float as well as Equalization |
| Battery Voltage Regulation Set Points | 40V to 65V |
| Equalization Charging | Adjustable voltage and duration |
| Battery Over Voltage | Fully protected. The optional Barcelona Breaker Box (MNBCLNA BB) automatically trips PV input breaker if battery exceeds 68VDC |
| Battery Short Circuit | Fully protected |
| Battery Temp Compensation | Automatic when BTS is installed. Adjustable mV per degree C per 2V cell |
| Programmable Auxiliary | 2 auxiliary outputs |
| Graphic Display | MNGP2 - 64 x 122 |
| Stacking cables for system networking | Standard CAT5 - Canbus |
| Communications | Canbus |
| Remote Display | MNGP2 can be relocated and a second display can be added |
| External Monitoring | Phone Application software allows local monitoring within normal blue tooth range from Barcelona. |
| Terminal Rating | 75C |
| Data Logging | 380 days of daily history |
| Positive Ground Applications | Requires 2 pole input and output breakers |
| Operating Temperature | Minimum of -40C to 50C (controller will auto derate as temperature rises above 25C) |
| Environmental Rating | Indoor type 1 |
| Warranty | 7 Years |
| Weight & Dimensions | 66 lbs. |
| Shipping Dimensions | 40 x 16.5 x 12 (inches) |
| Certifications | Listed by ETL for US & Canada |