| Nominal Battery Voltages | 12, 24, 36, 48, or 60 VDC (Single model - selectable via field programming at start-up) | 12, 24, 36, 48, or 60 VDC (Single model - selectable via field programming at start-up) | 
| Maximum Output Current | 80 amps @ 104 F (40C) with adjustable current limit | 60 amps @ 104 F (40C) with adjustable current limit | 
| Maximum Solar Array STC Nameplate | 12 VDC systems 1250 Watts / 24 VDC systems 2500 Watts / 48 VDC systems 5000 Watts / 60 VDC systems 6250 Watts | 12 VDC systems 900 Watts / 24 VDC systems 1800 Watts / 48 VDC systems 3600 Watts / 60 VDC Systems 4500 Watts | 
| NEC Recommended Solar Array STC Nameplate | 12 VDC systems 1000 Watts / 24 VDC systems 2000 Watts / 48 VDC systems 4000 Watts / 60 VDC Systems 5000 Watts | 12 VDC systems 750 Watts / 24 VDC systems 1500 Watts / 48 VDC systems 3000 Watts / 60 VDC Systems 3750 Watts | 
| PV Open Circuit Voltage (VOC) | 150 VDC absolute maximum coldest conditions / 145 VDC start-up and operating maximum | 150 VDC absolute maximum coldest conditions / 145 VDC start-up and operating maximum | 
| Standby Power Consumption | Less than 1 Watt typical | Less than 1 Watt typical | 
| Power Conversion Efficiency | 97.5% @ 80 Amps in a 48 VDC System - Typical | 98.1% @ 60 Amps in at 48 VDC System voltage - Typical | 
| Charging Regulation | Five Stages: Bulk, Absorption, Float, Silent and Equalization | Five Stages: Bulk, Absorption, Float, Silent and Equalization | 
| Voltage Regulation Set points | 10 to 80 VDC user adjustable with password protection | 10 to 80 VDC user adjustable with password protection | 
| Equalization Charging | Programmable Voltage Setpoint and Duration - Automatic Termination when completed | Programmable Voltage Setpoint and Duration - Automatic Termination when completed | 
| Battery Temperature Compensation | Automatic with optional RTS installed / 5.0 mV per C per 2V battery cell | Automatic with optional RTS installed / 5.0 mV per C per 2V battery cell | 
| Voltage Step-Down Capability | Can charge a lower voltage battery from a higher voltage PV array - Max 150 VDC input | Can charge a lower voltage battery from a higher voltage PV array - Max 150 VDC input | 
| Programmable Auxilary Control Output | 12 VDC output signal which can be programmed for different control applications (Maximum of 0.2 amps DC) | 12 VDC output signal which can be programmed for different control applications (Maximum of 0.2 amps DC) | 
| Status Display | 3.1" (8 cm) backlit LCD screen - 4 lines with 80 alphanumeric characters total | 3.1" (8 cm) backlit LCD screen - 4 lines with 80 alphanumeric characters total | 
| Remote Display and Controller | Optional Mate or Mate2 with RS232 Serial Communications Port | Optional Mate or Mate2 with RS232 Serial Communications Port | 
| Network Cabeling | Proprietary network system using RJ 45 Modular Connectors with CAT 5e Cable (8 wires) | Proprietary network system using RJ 45 Modular Connectors with CAT 5e Cable (8 wires) | 
| Data Logging | Last 128 days of Operation - Amp Hours, Watt Hours, Time in Float , Peak Watts, Amps, Solar Array Voltage, Max Battery Voltage Min Battery Voltage and Absorb for each day along with total Accumulated Amp Hours, and kW Hours of production | Last 128 days of Operation - Amp Hours, Watt Hours, Time in Float , Peak Watts, Amps, Solar Array Voltage, Max Battery Voltage Min Battery Voltage and Absorb for each day along with total Accumulated Amp Hours, and kW Hours of production | 
| Hydro Turbine Applications | Consult factory for approved Turbines | Consult factory for approved Turbines | 
| Positive Ground Applications | Requires two Pole Breakers for switching both positive and Negative Conductors on both Solar Array and Battery Connections (HUB-4 and HUB-10 can not be used for use in positive ground applications) | Requires two Pole Breakers for switching both positive and Negative Conductors on both Solar Array and Battery Connections (HUB-4 and HUB-10 can not be used for use in positive ground applications) | 
| Operating Temperature Range | Minimum -40 to maximum 60 C (Power capacity of the controller is automatically derated when operated above 40 C) | Minimum -40 to maximum 60 C (Power capacity of the controller is automatically derated when operated above 40 C) | 
| Environmental Rating | Indoor Type 1 | Indoor Type 1 | 
| Conduit Knockouts | One 1" (35mm)on the back; One 1" (35mm) on the left side; Two 1" (35mm) on the bottom | One 1" (35mm)on the back; One 1" (35mm) on the left side; Two 1" (35mm) on the bottom | 
| Warranty | Standard 5 year / Available 10 Year | Standard 5 year / Available 10 Year | 
| Weight - Unit | 12.20 lbs (5.56 kg) | 11.65 lbs (5.3 kg) | 
|             - Shipping | 15.75 lbs (7.10 kg) | 14.55 lbs (6.4 kg) | 
| Dimensions - Unit | 16.25" x 5.75" x 4" (41.3 x 14 x 10 cm) - (H x W x D) | 13.5 x 5.75 x 4" (40 x 14 x 10 cm) | 
|                    - Shipping | 21" x 10.5" x 9.75" (53 x 27 x 25 cm) | 18 x 11 x 8" (46 x 30 x 20 cm) | 
| Options | Remote Temperature Sensor (RTS), HUB 4, HUB 10, MATE, MATE 2 | Remote Temperature Sensor (RTS), HUB 4, HUB 10, MATE, MATE 2 | 
| Menu Languages | English & Spanish | English & Spanish |